Re: Design Question
Hi Venkat, This it process I usually follow.1) Do the fields have to generate delta records? YES: Are the fields in the standard SD tables associated to the extractor For example...
View ArticleRe: HCM IN - PA Issue: wage types are not coming by default in IT0008
Dear Mahmoud, I have removed the allowance grouping then also its not defaulting the wage types whereas manually also its not allowing to put any wage types giving error: wage types not maintain in...
View ArticleRe: Attendance and Absence on a same day
Hi, I'm experiencing a similar problem and need your help to resolve it.We enter time using CAT2 and I have people who can work part of the day and then take the rest as vacation or sick depending on...
View ArticleRe: How to enable green/yellow/red flag for tasks SAP CRM 7.0
Hi Maricarmen, you might want to have a look at the class CL_BT126S_A_APPTSR_CN00.Here the methodsGET_DUEGET_M_DUEGET_P_DUEGET_V_DUE encode all the logic you need. When you want to see the methods in...
View ArticleRe: Fold/Unfold not working in 2nd page onwards in webi 3.1
Hi Amber Garg, It could be one or more or none. The only way to be sure is to run a test. you should setup a test environment and test because no one of us can do it for you Thanks SC
View ArticleRe: mass maintenance xk99
Hello, You could take ADRC-ADDRNUMBER and execute LSMW for transaction MEAN. Regards
View ArticleRe: Portfolio Hierarchy Creation
Hello, You can upload using RPM_DX_BUCKET transaction, after create buckets using file you need to execute report /RPM/PLAN_INT_PREP Regards
View ArticleRe: SAPUI5 iView does not work?
My expectation of this iView would have been that a system is optional as some applications will not require system connectivity. And the URL would not be absolute for running web apps already deployed...
View ArticleRe: Meter Read Overflow handling
Are you sure it is an overflow issue and not a multiplier or bad data in the file (additional digit for the read which caused sap to show a ridiculous consumption) issue? Also what was the interval...
View ArticleRe: Issue in smartform
Hi Nikita, In your example,Width of line type L3 = 7cmTotal table width = 2cm (value in 'Width' to left of 'Table Painter' button) Suppose you are defining 2 columns of 1cm each, you will be...
View ArticleRe: Sap Hana db import and export
Hi, Please check the reply in other thread and reply back if this is helpful. Also kindly close the other thread. You can use the EXPORT and IMPORT SQL statements from the command line HDBSQL. Regards,...
View ArticleRe: Vendor Minimum Order Value Variable Functionality
Thanks Ajit Took longer that I'd like to get the change made, but it has worked perfectly thankyou.
View ArticleRe: Need to Update VAT Registration Number (STCEG) In FB02 ? Need any BAPI or...
HiUsing OB32 - did the field is configured for Editable ? REgards,Venkat
View ArticleRe: PO quantity and invoice quantity should match,
Hi Sudhir, Based on tolerance limit SAP system allows to post more Invoice than PO Quantity. Go to OMR6 and check the required settings. Also activate "GR based IR" condition to match invoice with PO...
View ArticleRe: String Extraction
Hi Antonio, Glad that was able to help you. You can post the code helped you to work. - Nrupal
View ArticleRe: how to find out if table is locked in HANA
Hi Nithish, Please refer to another thread on the same topic here. There is a workaround provided in that. http://scn.sap.com/thread/2107614 Regards, Ravi
View ArticleRe: Error starting Shadow while applying EHP 6
Upgrading the Kernel worked for me also Thanks for the post!!
View ArticleRe: Using CE_JOIN with two join fields?
I tried doing that too, but I get the following error:Description Resource Path Location TypeRepository: Internal error during statement execution, please see the database error traces for additional...
View ArticleRe: SAP Host Control and SMD Agents installed with Installation Server
You are correct, you have to do at least one to generate it. I would also recommend only using an inifile.xml if they are the same release of the SMD, for example don't use a 711 SMD xml file for a 730...
View ArticleRe: HELP: SAP Script Fatal Error
Hello Sid, there are a few parameters on the application server to control SAP GUI Scripting: sapgui/user_scripting must be TRUE to use scripting functions - in your case it is...
View Article